Erstens kommt es anders, zweitens als man denkt!
=> setenv ethaddr 08:00:06:60:5F:A1 Can't overwrite "ethaddr"
Lösung:
Linux, Palm, PPC, Windows, Lomo, Anoto, Symbian, Logitech, Widcomm, HTC, …
Erstens kommt es anders, zweitens als man denkt!
=> setenv ethaddr 08:00:06:60:5F:A1 Can't overwrite "ethaddr"
Lösung:
erwinrol.com/index.php?opensource/bdm.php
zeecube.com/archive/bdm/
vas-gmbh.de/software/mpcbdm/
cmp.felk.cvut.cz/~pisa/#m683xx
denx.de/wiki/view/PPCEmbedded/
denx.de/en/Hardware/HardwareDebugger
freescale.com/files/netcomm/doc/app_note/AN2387.pdf
Serial Ports am Siemens blu2net: (es ist ein CMOS zu RS232 Pegelwandler auf der Platine vorhanden MAX3222EEA)
![]()
vorneweg noch zwei Links:
siemens.at/bluetooth/
blue2net.dyndns.org/
Log:
PPCBoot 1.0.1.5 (Feb 7 2002 – 16:32:24)
Initializing…
CPU: XPC850xxZTB at 48 MHz: 2 kB I-Cache 1 kB D-Cache
Board: ### No HW ID – assuming ETX_094
HW-Version: V0.9 / W50037-Q1-D6-1
RSR: 0xc0000000
DRAM: 16 MB
FLASH: 2 MB
In: serial
Out: serial
Err: serial
Hit any key to stop autoboot: 0
=> help
go – start application at address ‘addr’
run – run commands in an environment variable
bootm – boot application image from memory
bootp – boot image via network using BootP/TFTP protocol
tftpboot- boot image via network using TFTP protocol
and env variables ipaddr and serverip
rarpboot- boot image via network using RARP/TFTP protocol
bootd – boot default, i.e., run ‘bootcmd’
loads – load S-Record file over serial line
loadb – load binary file over serial line (kermit mode)
md – memory display
mm – memory modify (auto-incrementing)
nm – memory modify (constant address)
mw – memory write (fill)
cp – memory copy
cmp – memory compare
crc32 – checksum calculation
base – print or set address offset
printenv- print environment variables
setenv – set environment variables
saveenv – save environment variables to persistent storage
protect – enable or disable FLASH write protection
erase – erase FLASH memory
flinfo – print FLASH memory information
bdinfo – print Board Info structure
iminfo – print header information for application image
coninfo – print console devices and informations
loop – infinite loop on address range
mtest – simple RAM test
bost – BOST-tests [? or testnumber]
icache – enable or disable instruction cache
dcache – enable or disable data cache
reset – Perform RESET of the CPU
echo – echo args to console
version – print monitor version
help – print online help
? – alias for ‘help’
=>
So hier der Bootlog von einem Siemens blue2net:
Continue reading ‘Siemens blue2net Log’
Recent Comments